440kW (125TR) Air-Cooled Glycol Chiller, Dual Screw Compressors Industrial Process Chiller
This 440kW (125TR) air-cooled glycol chiller is equipped with dual independent screw compressors, designed for industrial low-temperature process cooling. It uses air for heat rejection, no cooling tower required, and supports glycol solution to reach sub-zero set temperatures. With capacity step control, stable outlet temperature and robust construction, the unit runs reliably 24/7 for heavy-duty production. It is fully configurable for different refrigerants, voltages and control requirements to match global project demands.
The 440kw Air-Cooled Glycol Screw Chiller delivers a stable 2℃ glycol outlet, purpose-built for low-temperature applications such as cold storage, food processing, chemical and ice rink projects. Powered by a high-efficiency screw compressor with 8-step capacity control , it automatically matches cooling output to actual load for significant energy savings under partial-load operation. The unit is fully controlled by a Siemens PLC with touchscreen HMI, offering automatic start/stop, real-time monitoring and fault alarm protection for unattended, worry-free operation. Equipped with a high-efficiency oil separator, gas-liquid separator and economizer, the system ensures reliable lubrication, protects the compressor against slugging, and enhances COP for greater efficiency under low-temperature conditions. Its fully air-cooled, packaged design eliminates the need for a cooling tower, enabling quick installation and flexible placement in space-constrained or water-scarce sites — a dependable, energy-efficient glycol cooling solution for your low-temperature industrial needs.

Main Features - Glycol Air-Cooled Chiller
2. High-Efficiency Screw Compressor with 4-Step Capacity Control A reliable screw compressor automatically modulates between 25% / 50% / 75% / 100% to match the actual load — cutting energy use under partial-load conditions and reducing compressor wear from frequent on/off cycling. Dual Compressors total 8 steps capacity control.
3. Siemens PLC Intelligent Control Fully automatic operation via Siemens PLC + touchscreen HMI, with real-time monitoring of glycol temperature, pressure and current, automatic start/stop, fault self-diagnosis with alarm, and remote monitoring capability for unattended, worry-free running.
4. Air-Cooled, Tower-Free Design Fully packaged air-cooled unit — no cooling tower or condenser water piping required, saving water and simplifying installation. Compact footprint, quick to install and ideal for space-constrained or water-scarce sites.
5. Antifreeze Protection & Corrosion Resistance Glycol circuit designed with proper antifreeze concentration and corrosion-inhibited materials to protect the evaporator and piping, ensuring reliable operation below 0℃.
6. Reliability & Easy Maintenance Key components from reputable brands, complete protection devices (high/low pressure, overload, phase loss, anti-freeze), and accessible service points for low maintenance and easy upkeep.
Specification of the Dual Compressors Air Cooled Glycol Chiller:
Item Model
OMC-180ADL
Cooling Capacity
kcal/h
378400
KW
440
Ton
125
Input Power
KW
180
Max. running current
A
287.6
Power
3PH-380V-50Hz
Refrigerant
Type
R407C/R404A
Charge quantity
kg
108
Control Mode
Thermal Expansion Valve
Compressor
Type
Semi-Hermetic Screw
Power
KW
82*2
Start-up Mode
Y-△
Capacity control
%
0-25-50-75-100 (0-33-66-100)
Evaporator
Type
Carbon Steel Shell and Copper Tube / 304 SS shell and tube Optional
Chilled water flow
m3/h
76.5
Pipe Diameter
inch
4”
Condenser
Type
Air cooled high-efficient inner threaded copper-tubing aluminum fin type
Fan
Type
Low noise outer rotor
Power
KW
15.6
cooling air flow
m3/h
180000
safety protection
compressor over heat protection, over load protection, high and low pressure protection, reversed and lacking phase protection, anti-freezing protection, flow switch
Dimension
Length
mm
5500
Width
mm
2280
Height
mm
2200
Net Weight
kg
4680
Key Advantages & Features of the Dual Compressors Air Cooled Glycol Chiller
- Dual compressor redundant design:Two separate refrigeration circuits. One circuit can keep running for partial cooling if the other fails, avoiding full production shutdown.
- Air-cooled, tower-free layout:Save investment on cooling tower, pump and piping; easy outdoor installation on rooftop or yard, less civil work.
- Wide cooling temperature range with glycol:Compatible with ethylene / propylene glycol mixture, stable cooling down to -20℃ (customizable), ideal for low-temperature process.
- High-efficiency twin screw compressors:Smooth stepless capacity regulation from 25%~100%, excellent part-load COP to cut power consumption.
- Intelligent PLC touch control:Precise temperature control, self-diagnosis, fault record, remote monitoring option available.
- Corrosion-resistant heat exchangers & condenser coils:Fin coating optional for coastal / high-humidity harsh environment.
- Compact integrated skid structure:Pre-assembled, easy shipping, on-site connection only for pipes & power, short commissioning time.
- Global standard compliance:Support multiple voltage & frequency, available with CE / other regional certifications.
Screw compressor Glycol water chiller Product Information
●:Temperature control -35℃ to 0℃
●:Shell and tube evaporator and condenser
●:Bizer or Hanbell semi-hermetic screw compressor
●:Optional refrigerant R134a,R407c and R404a
●:Schneider Electrical Components
●:PLC/ Touch Screen Control Panel
●:No water tank, connect an external water tank
●:Need to connect a cooling tower
●:Safety protection devices of whole screw chiller
●:All models and cooling capacity available
Screw type water chiller Product display
Compressor features:
•New screw type compressor with 20%-30% higher in efficiency.
•Cooling capacity control available at four steps (100%-75%-50%-25%), three steps (100%-66%-33%) or no steps control system.
•High efficiency, low noise and vibration, easy to install.
•Environmental protection refrigerant R134a, R407c available.
Control operation system:
•SIEMENS PLC program control system, human-computer interface with big LED touch panel, running state displaying in multi-language, and self-diagnosis for easy operation and supervision.
•Extended industrial interface, convenient for being computer monitor via network.
Completely safety protection function:
•Multi-safety protection by high and low pressure, compressor overheating, overloading, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating and anti-freezing.
More Pictures of the Industrial Glycol Chiller

Suitable for continuous low-temperature process cooling in these industries:
✅ Beverage & brewery: Beer fermentation, carbonated drink cooling, syrup chilling
✅ Chemical & pharmaceutical: Reactor cooling, crystallization, extraction, API production
✅ Plastic & extrusion: Film extrusion, blow molding, calendering low-temperature forming
✅ Food processing: Frozen food, vegetable quick-freezing, dairy cooling
✅ Energy & new material: Battery material, slurry cooling
✅ Laser, plating & electronics: Electroplating bath, wet process, precision equipment cooling
✅ Ice rink, concrete cooling and other large industrial cooling projects
Packing & Shipping
Packing for LCL transportation Bulk carge
Packing & Loading Full container transportation
FAQ
Q1: What is the minimum outlet water temperature this chiller can reach?
A1: The unit is designed for a stable -10℃ outlet as standard. Lower outlet temperatures can be configured upon request — please confirm the exact required temperature and flow rate with us, and we will tailor the compressor, refrigerant and system design accordingly.
Q2: How does the 4-step capacity control help save energy?
A2: The screw compressor automatically modulates between 25% / 50% / 75% / 100% output to match the actual cooling load. During partial-load operation — common in most real working conditions — the unit consumes significantly less power instead of cycling on/off, which lowers electricity bills and reduces wear on the compressor.
Q3: Does this air-cooled chiller need a cooling tower?
A3: No. It is a fully air-cooled, packaged unit — no cooling tower, condenser water piping or water source is required. This makes installation quicker and greatly simplifies site requirements, ideal for space-constrained or water-scarce locations.
Q4: What does the Siemens PLC control system do?
A4: The Siemens PLC with touchscreen HMI provides fully automatic operation — real-time monitoring of water temperature, pressure and current, automatic start/stop, fault self-diagnosis with alarm, and operating history. It also supports remote monitoring for unattended, reliable operation.
Q5: Why are the oil separator, gas-liquid separator and economizer important?
A5: They protect the compressor and boost efficiency: the high-efficiency oil separator ensures proper lubrication and oil return; the gas-liquid separator prevents liquid slugging that could damage the compressor; and the economizer increases cooling capacity and improves COP, particularly valuable under low-temperature duty.
Q6: What refrigerant and power supply are used?
A6: Refrigerant and power supply are selected to match your target market and operating conditions (commonly R404A / R507A, and 380V/3PH/50Hz or 460V/3PH/60Hz). Please advise your local requirements, and we will confirm the optimal configuration.
Q7: What is the delivery time and warranty?
A: Standard delivery time depends on your configuration and destination. We provide a 15-month warranty (from commissioning date) and full after-sales support, including technical guidance for installation and commissioning, spare parts supply and responsive remote troubleshooting.

en